Part Number Hot Search : 
MPO40T02 2A333K 4B256 3524K082 BH4100FV 170BRM OM6109SA KBPC3500
Product Description
Full Text Search
 

To Download TFS125C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS125C.doc
version 1.2
12.07.00
VI TELEFILTER
Measurement condition
Ambient temperature TA: Input power level: Terminating impedances at fc: 23 C 0 dBm input: output:
Filter Specification
TFS 125C
1/5
605 -11 pF 620 -11 pF
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 125C is the maximum of the pass band attenuation amax. The maximum of the pass band attenuation amax is defined as the insertion loss ae. The centre frequence fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 125 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value ae fN
tolerance / limit max. min. 8,0 5,0 125,0 dB dB MHz
Insertion loss (Reference level) Nominal frequency
Centre frequency dB Passband ripple Relative attenuation arel fN ..... fN 150 fN 0,4 MHz...fN 0,6 fN 0,6 MHz...fN 1,2 fN 1,2 MHz...fN 1,8 fN 1,8 MHz...fN 3,4 fN 3,4 MHz...fN 9,5 fN 9,5 MHz.. fN 13 fN 13 MHz...fN +450 Group delay **) Group delay rippel **) within VSWR: IP3 ***)
fc within 150 kHz KHz MHz MHz MHz MHz MHz MHz MHz
125,0
MHz min. 1,25 1,25 2,0 .8,0 20,0 25,0 30,0 43,0 55,0 1,7 dB dB dB *) dB dB dB dB dB dB s ns
-
max. min. min. min. min. min. min. min. max.
150 kHz
max. 150,0 max. min. T.B.D T.B.D max. 10,0 2,3: 1 60,0
dB
Operating temperature range Temperature coefficient of frequency ( Tcf ) ****) Frequency inversion temperature To Input power level:
*) The rejection is relative to the point of maximum insertion at centre frequency **) measured with smoothing; smoothing aperture 30 KHz ***) modulation signals: fN and fN-28 MHz each of 10 dBm ****) fc(Hz) = Tcf(ppm/K) x (To - TA) x fCAT (MHz)
- 10 C ... + 85 C
dBm
Generated: Checked/Approved:
Sabah
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS125C.doc
version 1.2
12.07.00
VI TELEFILTER
Construction and pin connection (All dimensions in mm)
13.3
Filter Specification
TFS 125C
2/5
10 11 12
9
8
7 6
6.5 MAX.
TFS 125C M46
1 2 3 4
Datecode
5
10
1 2 3 4 5 6 7 8 9 10 11 12
Ground Ground Ground Ground Output RF Return Output Ground Ground Ground Ground Input Input RF Return
Date code: Year+week K 1998 L 1999 M 2000 N 2001 ......
50 matching network:
L1 11 Input 50 Ohm C1 12 1,2,3,4,7,8,9,10 5 L2 Output C2 6 50 Ohm
SAW
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS125C.doc
version 1.2
12.07.00
VI TELEFILTER
Stability characteristics
Filter Specification
TFS 125C
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer
Tape (all dimensions in mm) W Po Do E : : : : 24 0,3 4 0,1 1,5 + 0,1 1,75 0,1 11,5 0,1 0,60 2 12 1,5 7,1 13,9 0,1 0,1 0,2 0,2
COVER TAPE
1700 min 300 mm min 500 mm min 300 mm
EMBOSSED CARRIER TAPE
Do
Po
P2
E Ao F W
F : G (min) : P2 : P1 : D1(min) : Ao Bo CT : : :
D1
CT
Bo
G
P1
21,5 0,1
W2
Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 24,40 +2,0 30,4 60
C A
13
0,5/-0.2
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the left side of the tape.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS125C.doc
version 1.2
12.07.00
VI TELEFILTER
Air reflow temperature conditions
Filter Specification
TFS 125C
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS125C.doc
version 1.2
12.07.00
VI TELEFILTER
History
Version 1.0 1.1 Reason of Changes
Filter Specification
TFS 125C
5/5
Name
Date 07.10.1999 27.03.2000
1.2
- generation of specification according to hudson specification Sabah - correction according to customer specification (Nokia) Sabah - IP3: instead of `No statement' is 60 dBm - VSWR (max): instead of 2.0:1 is 2.3:1 min. 55 dB - Rejection (f fN 13000 KHz): instead of min. 60 dB is - Operational temperature range changed from -10 .... 80 C to -10 ..... 85 C - The sprocket holes: instead of the right side of the tape is on the left side of the tape (according to customer requirement, e mail from: 7. Juli.00) Sabah
12.07.2000
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information


▲Up To Search▲   

 
Price & Availability of TFS125C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X